Wall and dew point temperatures in steam generator flue gases BKZ-340-140-M/29 BKZ-340-140-M/29

Main Article Content

Jorge Santos Portuondo Pera
Luis Oliva Ruiz
https://orcid.org/0000-0002-1140-0363
Rene Lesme Jaén
https://orcid.org/0000-0001-7274-0153
Airen Fernández Cadete
https://orcid.org/0000-0001-9103-2750
Liety Ferrer Abad
https://orcid.org/0000-0002-9730-3264
Fé Jiménez Donatién
Jorge Luis Santana Romero
https://orcid.org/0000-0001-9344-4783

Abstract

Background: Cuban oil increases the condensation temperature of H2SO4 vapors, causing corrosion and fouling in structural elements of all thermoelectric power plants in Cuba.


Objective: To determine the behavior, for different loads, of the minimum temperature of the wall of the baskets of the regenerative air heater and the dew point of the gases produced by the combustion of Cuban crude oil and Mazut 20, in the Thermoelectric Power Plant "Antonio Maceo Grajales”.


Methods: The equations were used to determine several parameters of the processes that occur in the steam generator, as well as the graphs that link the variables related to the corrosion process, when considering the use of sulfurous fuel in the Thermoelectric Power Plant "Antonio Maceo Grajales".


Results: For all loads, when the air for combustion is preheated to 100 ºC, the dew point temperature for Cuban crude oil is higher than that of the minimum wall of the baskets in the cold zone, subjecting them to a process of corrosion and increasing the need for frequent replacement.


Conclusions: The thermal difference between the wall of the cold baskets and the dew point of the H2SO4 vapors, when burning Cuban crude oil, together with other variables, lead to the corrosion of the baskets. To avoid this, it is necessary to increase the temperature of the preheated air before it enters.

Downloads

Download data is not yet available.

Article Details

How to Cite
Portuondo Pera, J., Oliva Ruiz, L., Lesme Jaén, R., Fernández Cadete, A., Ferrer Abad, L., Jiménez Donatién, F., & Santana Romero, J. (2022). Wall and dew point temperatures in steam generator flue gases BKZ-340-140-M/29. Monteverdia, 15(2), 22-29. Retrieved from https://revistas.reduc.edu.cu, revistas.reduc.edu.cu/index.php/monteverdia/article/view/3546
Section
Scientific articles

References

Fajardo Rizo, M. (2002). Metodología de cálculo de sobreconsumos Central Termoeléctrica “Antonio Maceo Grajales”. (Manuscrito sin publicar). Central Termoeléctrica “Antonio Maceo Grajales”, Santiago de Cuba.


Fernández Diez, P. (2010). Guía para Centrales Térmicas. Departamento de Ingeniería Eléctrica y Energética. (Tesis de maestría) Universidad de Cantabria, España.


Manzano, N. (2011). Manual de eficiencia energética de determinación de la temperatura mínima del metal de los cestos de los CAR de los generadores de vapor BKZ-340-140/29M en función de la carga para minimizar el efecto corrosivo de los gases producto de la combustión en combustible de alto contenido de azufre. (Tesis de maestría). Universidad de Oriente, Santiago de Cuba.


Navarro, P. (2001). Estudio de la Corrosión en generadores de vapor que consumen crudo nacional. (Tesis de maestría). Universidad de Oriente, Santiago de Cuba.


Portuondo Pera, J. (2013). Factibilidad técnico económica del uso de láminas esmaltadas en los cestos fríos de los calentadores de aire regenerativos de las unidades de 100 MW de la Central Termoeléctrica “Antonio Maceo Grajales”. (Manuscrito sin publicar). Central Termoeléctrica “Antonio Maceo Grajales”, Santiago de Cuba.


Prieto, L. (2008). Análisis del comportamiento de la caída de presión en el eje convectivo del generador de vapor en la unidad# 6 de la CTE “10 de octubre” con la quema del crudo cubano. (Tesis de Maestría). Universidad de Oriente, Santiago de Cuba.